Smarts Residential Aluminium Door Technical Specifications

The sizes detailed below are for guidance only; maximum widths can vary depending on your chosen height and vice versa. Widths wider than 6250 can be achieved with a mechanical join and heights of up to 3000 can be achieved (subject to panel width and location). Panels can be made less than 700mm wide - please ask our technical department for advice.

Recommended Sizes
Min. Width (mm)none
Max. Width (mm)1000
Min. Height (mm)1655
Max. Height (mm)2400
Max. Panel Width (mm)900
Max. Sash Weight (kg)80
Sight Lines
Head / Top (mm)110
Jamb / Side (mm)110
Meeting Stiles (mm)n/a
Bottom - Std Threshold (mm)110
Std Threshold (mm)46
Low Thresholds (mm)13

Please Note: See Section Identifications for more information and detailed technical drawings.

The Sizes Below Apply For Double Front Doors

Recommended Sizes
Min. Width (mm)none
Max. Width (mm)2000
Min. Height (mm)1655
Max. Height (mm)2400
Max. Panel Width (mm)900
Max. Sash Weight (kg)80
Sight Lines
Head / Top (mm)110
Jamb / Side (mm)110
Meeting Stiles (mm)166
Bottom - Std Threshold (mm)110
Std Threshold (mm)46
Low Thresholds (mm)13

Please Note: See Section Identifications for more information and detailed technical drawings.

Door Performance

1.8
U Value
W/M²K
600
Air
Permeable
250
Water
Tightness
1200 Pa
Wind
Resistance

Please Note: These doors can be made to PAS23, PAS24 standards upon request.

These statistics apply for:
Open in, double-glazed units, 90% argon gas filled (4mm Planitherm 4S, 4mm Planilux), 16mm or more, Swiss V warm edge spacer bar (1.1 Glass - U Value centre Pane*). Achieving air permeability class 3, water tightness meets & exceeds requirements for class 5A, wind loads class 5 and frontal deflection classification C. Weather tested in accordance with BS EN 1026, BS EN 1027 and BS EN 102211.

Specifying - Suitable Applications

  1. Can be specified for light commercial and domestic applications.
  2. Meets building regulations for new build. (For Oct 2010)
  3. Meets building regulations for replacement and refurbishment projects. (For Oct 2010)
  4. Standard threshold; suitable for use on the ground floor up to second floor. (Recommended fully weather rated threshold).
  5. Low threshold options; suitable for use on the ground floor only, not recommended for properties situated by the coast or installed in exposed locations.

Key Profile Dimensions

Outer Frame Depth (mm) 147 or 70
Sash Depth (mm)47
Glazed Sealed Units (mm)28 (4 x 20 x 4)
Projection Cill Height - Optional (mm)25
Head Extension (mm) - if required 220 or 32
Midrail - if required (mm)109
Coupling Bar - if required (mm)35.5

Please Note:
1A direct fix outerframe is 70mm deep, while the subframe fix outerframe is 47mm deep. 
2A direct fix outerframe has a 20mm head extension, while a subframe fix outerframe has a 32mm head extension.

Technical Manuals - Downloads

  • View/Download Section Identification (Profiles, Combinations, Sight lines)
  • View/Download Test Results (Open in weather tested to BS EN 1026, BS EN 1027, BS EN 12211)
  • View/Download Glass Safety (Glass safety guidelines - where you must use safety glass)
URL call today to visit our
showroom

(Canvey Island, Essex)
01268 571055

Google+
Renovation and Home Design